D-Link · DCS-930L Devices · CWE-78 · published 2020-03-09
CVE-2016-11021D-Link DCS-930L Devices OS Command Injection Vulnerability
This week Known exploited in the wild.
CVE-2016-11021 is actively exploited in the wild: CISA added it to the Known Exploited Vulnerabilities catalog on 2022-03-25. EPSS estimates a 69.6% chance of exploitation in the next 30 days, higher than 99% of all CVEs. This DCS-930L Devices vulnerability: CVSS 7.2 (v3.1), a successful attack gives total control of the component. CISA’s required action: The impacted product is end-of-life and should be disconnected if still in use. US federal agencies must remediate by 2022-04-15. Patch this week.
Jump to: Remediation Exploit intelAffected versionsDescription
Remediation#
CISA required action: The impacted product is end-of-life and should be disconnected if still in use. (federal due date 2022-04-15)
Patch events
IoT & camerasD-Link DCS-930L Devices
OS Command InjectionCVE-2016-11021
Why: Known exploited in the wild.
Exploit intelligence#
| Signal | Value | Source |
|---|---|---|
| Known exploited | Yes, added 2022-03-25 | CISA KEV |
| Ransomware use | Unknown | CISA KEV |
| EPSS (30-day exploitation probability) | 70% (99th pct) | FIRST EPSS v2026.06.15 |
| CVSS base score | 7.2 (v3.1)CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H | CNA / CISA ADP |
| SSVC exploitation | active | CISA Vulnrichment |
| SSVC automatable | No | CISA Vulnrichment |
| SSVC technical impact | total | CISA Vulnrichment |
Weakness: CWE-78: Improper Neutralization of Special Elements used in an OS Command
More from this vendor: all D-Link vulnerabilities · recent KEV additions
Affected versions (from the CVE record)#
- Product
n/a(affected)
Description (from the CVE record)#
setSystemCommand on D-Link DCS-930L devices before 2.12 allows a remote attacker to execute code via an OS command in the SystemCommand parameter.
Quoted from the CVE Program record.